Share:


INT69-2 Diagnose

Arctic Refrigeration Components Supply Sdn Bhd is authorised distributor for Kriwan in Malaysia,Singapore, Indonesia,Vietnam,Thailand,Philippines,Cambodia, Myanmar(Burma),Laos,Brunei,India,Pakistan,Sri Lanka, Bangladesh,Middle East, Arica & Asia....   



KRIWAN MOTOR PROTECTOR INT69-2 DIAGNOSE ( 22A445S80 )
Application
The motor protector INT69-2 Diagnose is a further development of the reliable KRIWAN motor protectors. Its supplementary flexible-response protective functions help to improve the availability and extend the service life of a refrigeration system.
 
The INT69-2 Diagnose automatically saves operational and error data in a non-volatile memory. This data can be retrieved on a PC and analysed for diagnosis. The full scope of the diagnosis is achieved by using a KRIWAN-specific AMS sensor.
 
This motor protector is mainly employed on compressors which are qualified acc. to IEC/EN 60335.
 
 
Functional description
The temperature monitoring of the motor winding is done with two evaluation processes:
 
Static: Switch-off is immediate if the nominal response temperature of the built-in AMS or PTC sensors is reached.
 
Dynamic: If the temperature increases unusually quickly, the motor is switched off immediately even if the temperature is still far below the nominal response temperature. This prevents excess temperatures from occurring.
 
A short circuit at an AMS or PTC input also leads to a switch-off.
 
After expiration of the reset delay and elimination of the error or cool-down, the compressor can be restarted. For operation in the specified manner, the supply voltage has to be on permanently on the INT69-2 Diagnose.
 
 
PRODUCT DETAILS   
   
Application Compressors acc. IEC/EN 60335
Function  Motor temperature static, Motor temperature dynamic,                                    Short circuit.
Supply voltage AC 115 -240V
Permitted ambient temperature -30...+70°C
Temperature measuring circuits:
Type
1-2 AMS sensors in series alternative 1-9                                                            PTC sensors acc. to DIN 44081, DIN 44082 in series
Temperature measuring circuits:
R_25, total
<1.8kΩ
Temperature measuring circuits:
R_trip
4.5kΩ ±20%
Temperature measuring circuits:
R_trip, static
4.5kΩ ±20%
Temperature measuring circuits:
R_reset
2.75kΩ ±20%
Temperature measuring circuits:                  Max. length connection line 30m
Short circuit monitoring system PTC Typically <30Ω
Input, operating recongnition motor:          Lower limit AC 100V at 20Hz to 175V at 90Hz
Input, operating recongnition motor:           Upper limit AC 460V ±15%
Operating with frequency converters Suitable
Reset delay: Motor temperature static 1min ±12s
Reset delay: Motor temperature dynamic 5min ±1min
Resetting the lock or the reset delay Main reset >5s only possible if there is no error current
Relay: Connection AC 240V 2.5A C300 at least AC/DC 24V 20mA
Relay: Mechanical service life Approx. 1 million switching cycles
Interface Diagnose port (DP)
Protection class acc. To EN 60529 IP00
Connection type screw type terminals
Housing material PA glass-fibre-reinforced
Mounting screw mounted
Dimensions Refer to dimensions in mm
Weight Approx. 150g
Check base IEC/EN 60335, IEC/EN 60730, UL 60730 EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2
Approval UL File no. E75899 cURus VDE certification no. 40022017



 Inquiry - INT69-2 Diagnose