Description    
  • Innovative digital controllers dedicated to heat and NT and LT refrigeration
  • Easy and intuitive programming mode
  • On/off key
  • Energy saving cycles through digital input
  • Fast freezing with dedicated set point
  • Outputs restart with door open alarm
  • Temperature Max and Min functions
  • Configurable digital input also as probe
  • Virtual probe management
  • C​ycles for milk cooling and storage systems
  • Functions for refrigerated air dryers in automation processes
  • Condenser temperature management to prevent critical plant situations
  • Hot Key or Prog Tool Kit connector for quick and easy programming
  • Serial connection to monitoring systems (direct for XR35/75/77CX or via XJ485CX)
  • Connection for X-REP remote display (alternative to TTL output)
  • 3VA max power absorption
  • Display with red LED (10,5mm high) and icons


CONTROLLER FOR NT WITH ''OFF CYCLE'' DEFROST, ADDITIONAL CONFIGURABLE RELAY AND RS485

Generals 
Power supply: 110, 230Vac 

Probe inputs 
ThermostatNTC, Pt1000 
DefrostNTC, Pt1000 
CondenserNTC, Pt1000 

Digital inputs 
Alarm, start defrost, AUX, door switch, pressure switch, probe: configurable 
Alarm, start defrost, AUX, door switch, pressure switch: configurable 

Relay outputs 
Compressor8A, 16A
Light/Alarm8A 

Other 
Hot Key / Prog Tool Kit: present 
Remote display output: X-REP 
Serial output: RS485 
Buzzer: optional 
RTC: optional


 

FEATURES XR20CX XR30CX XR35CX XR40CX
Display: n° digits ± 3 d.p. ± 3 d.p. ± 3 d.p. ± 3 d.p.
Power supply 110, 230Vac ​110, 230Vac 110, 230Vac  110, 230Vac 
Probe inputs 
Thermostat  NTC, PTC   NTC, PTC   NTC, Pt1000 NTC, PTC
Defrost      NTC, Pt1000 NTC, PTC
Condenser NTC, PTC (on HOT KEY)   NTC, PTC (on HOT KEY)   NTC, Pt1000 NTC, PTC (on HOT KEY) 
 Digital inputs 
Alarm, start defrost, door switch, pressure switch,
energy saving, ON/OFF, probe
config config config config
Alarm, start defrost, door switch, pressure switch, 
energy saving, ON/OFF
    config  
Relay outputs 
Compressor 8A, 20A  8A, 20A  8A, 16A  8A, 20A 
Defrost    8A   8A
Light/Alarm   8A 8A  
Other
Hot Key / Programming Tool Kit present present present present
Remote display output X-REP optional   X-REP optional  
X-REP
present
Serial output TTL TTL TTL TTL
Buzzer optional   optional   optional   optional
Real Time Clock   optional   optional    